The Investigational Medicinal Product Dossier (IMPD) supports a clinical trial application; Module 3 of the CTD supports a marketing authorisation. In the EU the IMPD is submitted through CTIS under the Clinical Trials Regulation (EU) No 536/2014. Both use the same drug substance (S) and drug product (P) headings, but the expected depth differs, and it grows with the phase of development.

IMPD (quality)CTD Module 3
PurposeAuthorisation of a clinical trialAuthorisation to place the product on the market
Legal basis (EU)Regulation (EU) No 536/2014, submitted through CTISDirective 2001/83/EC and Regulation (EC) No 726/2004
StructureS and P sections following CTD headings; full or simplified IMPDFull Module 3 plus Module 2.3 summary
Manufacturing processOutline of the process and controlsFull description with critical steps and in-process controls
Process validationNot required, except validation of sterilisation and aseptic processesRequired for the commercial process (or a validation scheme where allowed)
Pharmaceutical developmentBrief justification of formulation and processFull development section (P.2) justifying the product and the control strategy
CharacterisationStructure and key impurities, growing with the phaseComplete characterisation and impurity profile
SpecificationsProvisional, phase-appropriate limits, tightened during developmentFinal limits justified by batch data and pharmacopoeia
Analytical methodsSuitable for use; full validation not required in early phasesFully validated according to ICH Q2
Batch dataBatches used in non-clinical and clinical studiesRepresentative batches, including commercial scale
StabilityData covering the planned duration of use; shelf-life extension under a stability protocolFormal ICH Q1 studies supporting retest period and shelf life
Placebo and comparatorsComposition, and data for modified or blinded comparatorsNot applicable
GMP evidenceManufacturing or import authorisation; QP declaration for products made outside the EUGMP certificates for all sites; QP batch release in the EU
ChangesSubstantial modifications submitted through CTISVariations under the variations framework
Simplified optionSimplified IMPD when the product is already authorised or described earlierAbridged applications (for example generics) still need full Module 3

The safety-related elements, such as impurities, sterility and, for biologics, viral safety, are expected in full from the first trial. Most other elements can be phase-appropriate and grow toward the Module 3 standard as development moves to pivotal trials and the marketing authorisation application.

Hanpars prepares quality IMPDs and CTD Module 3 dossiers. See CTD/eCTD dossiers and IMPD.