The Investigational Medicinal Product Dossier (IMPD) supports a clinical trial application; Module 3 of the CTD supports a marketing authorisation. In the EU the IMPD is submitted through CTIS under the Clinical Trials Regulation (EU) No 536/2014. Both use the same drug substance (S) and drug product (P) headings, but the expected depth differs, and it grows with the phase of development.
| IMPD (quality) | CTD Module 3 | |
|---|---|---|
| Purpose | Authorisation of a clinical trial | Authorisation to place the product on the market |
| Legal basis (EU) | Regulation (EU) No 536/2014, submitted through CTIS | Directive 2001/83/EC and Regulation (EC) No 726/2004 |
| Structure | S and P sections following CTD headings; full or simplified IMPD | Full Module 3 plus Module 2.3 summary |
| Manufacturing process | Outline of the process and controls | Full description with critical steps and in-process controls |
| Process validation | Not required, except validation of sterilisation and aseptic processes | Required for the commercial process (or a validation scheme where allowed) |
| Pharmaceutical development | Brief justification of formulation and process | Full development section (P.2) justifying the product and the control strategy |
| Characterisation | Structure and key impurities, growing with the phase | Complete characterisation and impurity profile |
| Specifications | Provisional, phase-appropriate limits, tightened during development | Final limits justified by batch data and pharmacopoeia |
| Analytical methods | Suitable for use; full validation not required in early phases | Fully validated according to ICH Q2 |
| Batch data | Batches used in non-clinical and clinical studies | Representative batches, including commercial scale |
| Stability | Data covering the planned duration of use; shelf-life extension under a stability protocol | Formal ICH Q1 studies supporting retest period and shelf life |
| Placebo and comparators | Composition, and data for modified or blinded comparators | Not applicable |
| GMP evidence | Manufacturing or import authorisation; QP declaration for products made outside the EU | GMP certificates for all sites; QP batch release in the EU |
| Changes | Substantial modifications submitted through CTIS | Variations under the variations framework |
| Simplified option | Simplified IMPD when the product is already authorised or described earlier | Abridged applications (for example generics) still need full Module 3 |
The safety-related elements, such as impurities, sterility and, for biologics, viral safety, are expected in full from the first trial. Most other elements can be phase-appropriate and grow toward the Module 3 standard as development moves to pivotal trials and the marketing authorisation application.
Hanpars prepares quality IMPDs and CTD Module 3 dossiers. See CTD/eCTD dossiers and IMPD.